Message 001
Communication from the Commission - TRIS/(2026) 2369
Directive (EU) 2015/1535
Notification: 2026/0454/SI
Notification of a draft text from a Member State
Notification – Notification – Notifzierung – Нотификация – Oznámení – Notifikation – Γνωστοποίηση – Notificación – Teavitamine – Ilmoitus – Obavijest – Bejelentés – Notifica – Pranešimas – Paziņojums – Notifika – Kennisgeving – Zawiadomienie – Notificação – Notificare – Oznámenie – Obvestilo – Anmälan – Fógra a thabhairt
Does not open the delays - N'ouvre pas de délai - Kein Fristbeginn - Не се предвижда период на прекъсване - Nezahajuje prodlení - Fristerne indledes ikke - Καμμία έναρξη προθεσμίας - No abre el plazo - Viivituste perioodi ei avata - Määräaika ei ala tästä - Ne otvara razdoblje kašnjenja - Nem nyitja meg a késéseket - Non fa decorrere la mora - Atidėjimai nepradedami - Atlikšanas laikposms nesākas - Ma jiftaħx il-perijodi ta’ dewmien - Geen termijnbegin - Nie otwiera opóźnień - Não inicia o prazo - Nu deschide perioadele de stagnare - Nezačína oneskorenia - Ne uvaja zamud - Inleder ingen frist - Ní osclaíonn sé na moilleanna
MSG: 20262369.EN
1. MSG 001 IND 2026 0454 SI EN 26-08-2026 SI NOTIF
2. Slovenia
3A. Slovenski inštitut za standardizacijo, Ulica Gledališča BTC 2, SI-1000 Ljubljana
3B. Urad Republike Slovenije za meroslovje, Grudnovo nabrežje 17, SI-1000 Ljubljana
4. 2026/0454/SI - I10 - Metrology
5. Regulation amending the Regulation on Metrological Requirements for Breathalysers
6. Metrology
7.
8. In preparing the amendment to the Regulation, it was established that, without the proposed measure, there was a risk of significant delays in the verification of breathalysers, which would consequently result in a reduction in road safety.
Based on many years of experience in carrying out the verification of breathalysers, it has been demonstrated that, where the first three measurements at a given concentration are within the maximum permissible errors (hereinafter: MPEs), the remaining measurements are also within the MPEs, therefore, reducing the number of measurements does not reduce the level of confidence in the correctness and accuracy of the measuring instrument. The proposal follows International Recommendation OIML R 126:2021 Part 2: Metrological controls and performance tests, which likewise recommends, in point 3.4.3.1, at least three measurements at each of at least three concentrations.
The measure contributes to optimising the procedure for the verification of breathalysers, consequently resulting in a shorter response time for carrying out the verification, which is important for applicants, as well as in a more cost-effective procedure for the state, without reducing confidence in the correct measurement by the measuring instrument.
The public interest pursued by the proposal is to improve road safety.
The Regulation does not impose any additional restrictions on the internal market of the European Union and does not affect cross-border trade or services.
The existing Regulation on Metrological Requirements for Breathalysers requires 10 tests at 5 concentrations, which is very time-consuming and consequently results in verification procedures taking a long time. As a result, measuring instruments undergoing verification are withdrawn from use for an extended period. The proposed measure shortens the verification procedure and enables measuring instruments to be returned to use more quickly.
The proposed Regulation does not constitute a disproportionate burden in relation to the objective pursued. The Regulation on Metrological Requirements for Breathalysers stems from the need to ensure road safety. The proposed amendments merely introduce certain updates in the area of verification and initial verification and do not in any way impose additional burdens.
Without appropriate regulation, the risks that the measure seeks to address could remain largely unchanged, which could have a negative impact on road safety.
9. The key aspect of the proposed amendment to the Regulation on Metrological Requirements for Breathalysers (Official Gazette of the Republic of Slovenia Nos 81/13 and 5/16) consists primarily in reducing the number of repetitions required when testing the accuracy of a breathalyser in the course of initial, regular and extraordinary verification. In addition, with a view to preventing any potentially deviant results when a breathalyser is used, the Regulation introduces a safety difference, or value, which is deducted from the final result indicated by the breathalyser.
9a. In preparing the amendment to the Regulation, it was established that, without the proposed measure, there was a risk of significant delays in the verification of breathalysers, which would consequently result in a reduction in road safety.
Based on many years of experience in carrying out the verification of breathalysers, it has been demonstrated that, where the first three measurements at a given concentration are within the maximum permissible errors (hereinafter: MPEs), the remaining measurements are also within the MPEs, therefore, reducing the number of measurements does not reduce the level of confidence in the correctness and accuracy of the measuring instrument. The proposal follows International Recommendation OIML R 126:2021 Part 2: Metrological controls and performance tests, which likewise recommends, in point 3.4.3.1, at least three measurements at each of at least three concentrations.
The measure contributes to optimising the procedure for the verification of breathalysers, consequently resulting in a shorter response time for carrying out the verification, which is important for applicants, as well as in a more cost-effective procedure for the state, without reducing confidence in the correct measurement by the measuring instrument.
The public interest pursued by the proposal is to improve road safety.
9b. The Regulation does not impose any additional restrictions on the internal market of the European Union and does not affect cross-border trade or services.
The existing Regulation on Metrological Requirements for Breathalysers requires 10 tests at 5 concentrations, which is very time-consuming and consequently results in verification procedures taking a long time. As a result, measuring instruments undergoing verification are withdrawn from use for an extended period. The proposed measure shortens the verification procedure and enables measuring instruments to be returned to use more quickly.
9c. The proposed Regulation does not constitute a disproportionate burden in relation to the objective pursued. The Regulation on Metrological Requirements for Breathalysers stems from the need to ensure road safety. The proposed amendments merely introduce certain updates in the area of verification and initial verification and do not in any way impose additional burdens.
Without appropriate regulation, the risks that the measure seeks to address could remain largely unchanged, which could have a negative impact on road safety.
10. References in the basic text:
11. No
12.
13. No
14. No
15. No
16.
TBT aspects: No
SPS aspects: No
**********
European Commission
Contact point Directive (EU) 2015/1535
email: grow-dir2015-1535-central@ec.europa.eu